Technical sheet, edition 1
In force
VELUX Modular Skylight HVC
HVC module, opening, made to order
- Product
- GTIN 5702328897687
- Technical sheet
- Edition 1, in force Technical sheet history ›
DppID : 5702328999992jUJilOb4MxZt3HrLa (demonstration identifier)
Technical identifiers
Complete dataTechnical sheets of this product
The batch number printed on the packaging gives you the exact edition
- Edition 1, in force since 2026-11-10 View this technical sheet Source: Cobuilder Supply sheet
Hazardous substances (SVHC) NONE
Declared performance by characteristic
EN 14351-1+A2 (Fenêtres et portes, normes de produit, caractéristiques de performance) | Declaration of Performance (DoP) VELUX-DOP-SIMULE-14351-1 dated 2026-06-15
Simulated declaration. DoP no. VELUX-DOP-SIMULE-14351-1 of 2026-06-15: the number, the issue date and the assessment and verification of constancy of performance system are fictitious (prototype).
| Characteristic | Declared performance |
|---|---|
Air permeability
|
class 4 |
External fire performance, European
|
BROOF(t1) ; BROOF(t4) |
Impact resistance
|
NPD |
Light transmittance
|
0.72 |
Load-bearing capacity of safety devices
|
NPD |
Reaction to fire
|
N/A |
Sound insulation
|
36 (-1;-4) decibel |
Resistance to snow load
|
6 mm toughened-14 mm -6 mm heat strengthened 14 mm-6.76mm (33.2) laminated float |
Resistance to wind load
|
Class C5 |
Thermal transmittance (Uw)
|
0.89 W/(m2K) |
Total solar energy transmittance for a pane with a closed accessory
|
0.51 |
Watertightness
|
E1200 |
LNE (organisme notifié, démo simulée), notified body no. 0071
Commission software: not published
Declared performance by characteristic
EN 12101-2 (Systèmes pour le contrôle des fumées et de la chaleur, partie 2 : spécifications pour les dispositifs d'évacuation naturelle de fumées et de chaleur) | Declaration of Performance (DoP) VELUX-DOP-SIMULE-12101-2 dated 2026-06-15
Simulated declaration. DoP no. VELUX-DOP-SIMULE-12101-2 of 2026-06-15: the number, the issue date and the assessment and verification of constancy of performance system are fictitious (prototype).
| Characteristic | Declared performance |
|---|---|
Nominal activation system / sensitivity
|
N/A |
Response delay (response time)
|
N/A second |
Operational reliability
|
N/A |
Aerodynamic free area without deflector Aa Roof
|
N/A m2 |
Aerodynamic free area without deflector Aa Wall
|
N/A m2 |
Aerodynamic free area with Deflector KCD 0040 Aa Roof
|
N/A m2 |
Aerodynamic free area with Deflector KCD 0080 Aa Roof
|
N/A m2 |
Resistance to heat
|
N/A |
Mechanical stability
|
N/A |
Opening under load N1300
|
N/A Pa |
Low ambient temperature
|
N/A |
Stability under wind load
|
N/A |
Resistance to wind-induced vibration (where included)
|
N/A |
LNE (organisme notifié, démo simulée), notified body no. 0071
Commission software: not published
Technical characteristics
EN 14351-1+A2 (Fenêtres et portes, normes de produit, caractéristiques de performance)
Regulatory status legend
Click a status to keep only those rows.
- Mandatory
- Data required by the applicable EU regulation.
- Optional
- Data not required by regulation, provided as additional context.
- Voluntary
- Data provided freely by the manufacturer, with no regulatory obligation.
- Auto-generated
- Data calculated or derived automatically by the system from other information.
| Property | Typical value (data sheet) | |
|---|---|---|
| Declared performances | ||
| Declaration of performance and conformity - EN 14351-1+A2 (windows) | ||
| Air permeability - Regulatory status : Mandatory | class 4 | |
| External fire performance, European - Regulatory status : Mandatory | BROOF(t1) ; BROOF(t4) | |
| Light transmittance - Regulatory status : Mandatory | 0.72 | |
| Sound insulation - Regulatory status : Mandatory | 36 (-1;-4) decibel | |
| Resistance to snow load - Regulatory status : Mandatory | 6 mm toughened-14 mm -6 mm heat strengthened 14 mm-6.76mm (33.2) laminated float | |
| Resistance to wind load - Regulatory status : Mandatory | Class C5 | |
| Thermal transmittance (Uw) - Regulatory status : Mandatory | 0.89 W/(m2K) | |
| Total solar energy transmittance for a pane with a closed accessory - Regulatory status : Mandatory | 0.51 | |
| Watertightness - Regulatory status : Mandatory | E1200 | |
| Voluntary characteristics | ||
| Identification | ||
| GTIN (AI 03, made-to-order) - Regulatory status : Mandatory | 5702328897687 | |
| Product type code - Regulatory status : Mandatory | HVC100240 0016LCB | |
| Product name (as in the sales order position) - Regulatory status : Mandatory | VELUX Modular Skylight HVC | |
| Product image - Regulatory status : Voluntary | velux-hvc.jpg | |
| Supply product page (Cobuilder) - Regulatory status : Mandatory | https://public.cobuilder.com/en/products/a893559f-3f8c-44d6-c47f-08dee16b57b6 | |
| Declaration of performance, reference and revision - Regulatory status : Mandatory | revision 2026-06-15 | |
| Environmental performance - EPD indicators | ||
| GWP-total - Regulatory status : Voluntary | 1,95E+02 kg CO₂ eq/m² | |
| GWP-fossil - Regulatory status : Voluntary | 1,99E+02 kg CO₂ eq/m² | |
| GWP-biogenic - Regulatory status : Voluntary | -3,69E+00 kg CO₂ eq/m² | |
| GWP-luluc - Regulatory status : Voluntary | 9,18E-02 kg CO₂ eq/m² | |
| ODP - Regulatory status : Voluntary | 9,07E-08 kg CFC 11 eq | |
| AP - Regulatory status : Voluntary | 1,40E+00 mol H+ eq | |
| EP-freshwater - Regulatory status : Voluntary | 5,41E-02 kg PO₄³ -eq | |
| EP-marine - Regulatory status : Voluntary | 4,99E-02 kg N eq | |
| EP-terrestrial - Regulatory status : Voluntary | 5,34E-01 mol N eq | |
| POCP - Regulatory status : Voluntary | 2,11E-01 kg NMVOC eq | |
| ADPE - Regulatory status : Voluntary | 2,43E-03 kg Sb equiv | |
| ADPF - Regulatory status : Voluntary | 2,96E+03 MJ, net calorific value | |
| WDP - Regulatory status : Voluntary | 4,26E+00 m³ world eq deprived | |
| PERE - Regulatory status : Voluntary | 6,82E+02 MJ | |
| PERM - Regulatory status : Voluntary | 3,92E+01 MJ | |
| PERT - Regulatory status : Voluntary | 7,21E+02 MJ | |
| PENRE - Regulatory status : Voluntary | 3,26E+03 MJ | |
| PENRM - Regulatory status : Voluntary | 1,55E+02 MJ | |
| PENRT - Regulatory status : Voluntary | 3,42E+03 | |
| SM - Regulatory status : Voluntary | 3,32E+00 kilogram | |
| RSF - Regulatory status : Voluntary | 2,33E-12 MJ, net calorific value | |
| NRSF - Regulatory status : Voluntary | 2,74E-11 MJ, net calorific value | |
| FW - Regulatory status : Voluntary | 8,05E+02 m³ | |
| HWD - Regulatory status : Voluntary | 5,26E-03 kilogram | |
| NHWD - Regulatory status : Voluntary | 7,23E+01 kilogram | |
| RWD - Regulatory status : Voluntary | 2,11E-01 kilogram | |
| CRU - Regulatory status : Voluntary | 0,00E+00 kilogram | |
| MFR - Regulatory status : Voluntary | 7,51E+00 kilogram | |
| MER - Regulatory status : Voluntary | 0,00E+00 kilogram | |
| EEE - Regulatory status : Voluntary | 0,00E+00 MJ | |
| EET - Regulatory status : Voluntary | 0,00E+00 MJ | |
| EPD reference - Regulatory status : Voluntary | EPD-VEL-20210076-CCI3-EN | |
| Compliance and sustainability documents | ||
| DoC / RoHs - Regulatory status : Mandatory | https://contenthub.velux.com/api/public/content/product-guide_453396?v=b9846e73 | |
| REACH - Regulatory status : Mandatory | https://contenthub.velux.com/api/public/content/a1262-34f44-3a44c_downloadOriginal?v=0a75bc2f | |
| Recycled content - Regulatory status : Voluntary | https://contenthub.velux.com/api/public/content/5b48b-67144-8b43a_downloadOriginal?v=f600399b | |
| Green building rating scheme - BREEAM and DGNB (combined document) - Regulatory status : Voluntary | https://contenthub.velux.com/api/public/content/06852-d13ba-6b404_downloadOriginal?v=42bc5532 | |
16 lines not applicable (N/A or NPD)
| Property | Typical value (data sheet) | |
|---|---|---|
| Declared performances | ||
| Declaration of performance and conformity - EN 14351-1+A2 (windows) | ||
| Impact resistance - Regulatory status : Mandatory | NPD | |
| Load-bearing capacity of safety devices - Regulatory status : Mandatory | NPD newton | |
| Reaction to fire - Regulatory status : Mandatory | N/A | |
| Declaration of performance - EN 12101-2 (smoke and heat exhaust ventilators) | ||
| Nominal activation system / sensitivity - Regulatory status : Mandatory | N/A | |
| Response delay (response time) - Regulatory status : Mandatory | N/A second | |
| Operational reliability - Regulatory status : Mandatory | N/A | |
| Aerodynamic free area without deflector Aa Roof* - Regulatory status : Mandatory | N/A m2 | |
| Aerodynamic free area without deflector Aa Wall - Regulatory status : Mandatory | N/A m2 | |
| Aerodynamic free area with Deflector KCD 0040 Aa Roof - Regulatory status : Mandatory | N/A m2 | |
| Aerodynamic free area with Deflector KCD 0080 Aa Roof - Regulatory status : Mandatory | N/A m2 | |
| Resistance to heat - Regulatory status : Mandatory | N/A | |
| Mechanical stability - Regulatory status : Mandatory | N/A | |
| Opening under load N1300 - Regulatory status : Mandatory | N/A Pa | |
| Low ambient temperature - Regulatory status : Mandatory | N/A | |
| Stability under wind load - Regulatory status : Mandatory | N/A | |
| Resistance to wind-induced vibration (where included) - Regulatory status : Mandatory | N/A | |